4" Layflat Hose Camlock

Calculate Required BTU



Click here for MC² Energy Solutions' Heating Efficiencies/Fuel BTU Properties

Fuel chart ( BTU properties)
Diesel – 36,500 BTU per litre
Propane- 22,300 BTU per litre
Natural gas- 1 cubic foot = 1000 BTU


MC2 Heaters
20 MM BTU diesel fired
Fuel consumption- 250ltrs – 300 ltrs per hour max ( dependant on outside temp)
Oilfield rating- 20 MM BTU
True BTU output- 10-11 MM BTU ( dependant on outside temp)


40 MM BTU diesel fired
Fuel consumption- 500-600 ltrs per hour max ( dependant on outside temp)
Oilfield rating- 40 MM BTU
True BTU output- 20-22 MM BTU ( dependant on outside temp)


60 MM BTU Natural gas or propane fired
Fuel consumption –
Natural gas – 30,000 cubic feet per hour max
True BTU output 28 MM BTU
Propane- 1250ltrs per hour max
True BTU ouput 25 MM BTU


NOTE: All MC2 Energy Solutions heaters have been given an oilfield rating as well as a true btu output rating. Oilfield rating is based on comparable BTU output from competitors and true btu out put is the amount of the BTU value absorbed into the fluid. MC² Energy Solutions' heaters run at 90% efficiency.

Need a rental or service?

Contact with us through our online form or submit a business inquiry online.

Contact Us

4" Layflat Hose Camlock

Layflat hose with camlocks ends.

We provide innovative energy solutions for sustainable progress. Our professional team works to increase productivity and cost effectiveness for each and every client.


Contact Us